Directions for Obtaining
A Nasopharyngeal Aspirate (NPA)
Supplies:
Suction apparatus
Mucus trap
Suction Catheter
Viral transport media media (obtained from the Medical Distribution
Center {MDC} ext 550-1214 order #29816)
Procedure
1.
Obtain the viral transport medium (VTM) and label
the mucus trap with patient information. Check the VTM expiration
date before use.
2.
Attach the suction catheter to the mucus trap,
and connect it to the suction apparatus.
3.
Measure the distance, from the patient's nostril
to the nasopharynx ( which is half the distance from the nostril
to the base of the ear) and hold the tubing at that location. Do
not move fingers or advance the tube beyond that point.
4.
Start the suction and pass the tube along the base
of one nostril into the nasopharynx.
5.
Apply suction to obtain secretions from the nasopharynx.
Sample both nostrils with the same suction catheter, without moving
the measured position.
6.
Rinse the suction catheter by suctioning the viral
transport media through the catheter. The beads in the media may
be aspirated but this is not necessary.
7.
Complete Pathology 6 requisition slip and indicate
for Influenza antigen and culture. The same specimen can
be sent for RSV also.
8.
Deliver the specimen to the microbiology lab within
ONE HOUR of obtaining the specimen. The pneumatic tube may not
be used.